    型號(hào):

    無(wú)鹵低煙電纜在正常使用時(shí),導(dǎo)體長(zhǎng)期允許工作溫度為90℃,短路時(shí)(最大短路時(shí)間5S),導(dǎo)體最高溫度不超過(guò)250℃;

    關(guān)鍵詞:

    無(wú)鹵低煙電力電纜

    所屬分類(lèi):

    產(chǎn)品描述

      無(wú)鹵低煙阻燃塑料絕緣電力電纜

      HALOGEN FREE LOW-SMOKE FLAME RETARDANT PLASTIC INSULATED POWER CABLE

      執(zhí)行標(biāo)準(zhǔn)

      STANDARD IMPLEMENTED

      本產(chǎn)品參照采用GB/T12706.1-2002、IEC60502-1997標(biāo)準(zhǔn),制定企業(yè)標(biāo)準(zhǔn),阻燃特性達(dá)到GB/T18380.3-2001中A類(lèi)要求;燃燒煙密度(透光率)達(dá)到GB/T17651-1998低煙標(biāo)準(zhǔn).燃燒氣體腐蝕性達(dá)到GB/T17650-1990標(biāo)準(zhǔn)要求;低煙低鹵電纜燃燒時(shí)的透光率、HCL腐蝕氣體釋放量符合Q/321084 KXDO6-2008標(biāo)準(zhǔn)要求。

      The product conforms to the GB/T12706.1-2002.andIEC60502-1997 standard . lts flame-retarding property has reached thecorresponding requirement sin GB/T13830.3-2001;Burningsmoke intensity (luminousness) is up to the low-smoke standard of GBIT17651 -1998; Burning gas lorrosion intensityis in conformity with the standard requirement in GB/T17650-1990; the luminousness of burning low-halogen and low-smoke cable and the liberation of HCL active gas all conformto the standard requirement of KXDO6-2008.

      使用特性

      SERVICE CHARACTERIST

      無(wú)鹵低煙電纜在正常使用時(shí),導(dǎo)體長(zhǎng)期允許工作溫度為90℃,短路時(shí)(最大短路時(shí)間5S),導(dǎo)體最高溫度不超過(guò)250℃;

      低煙低鹵電纜在正常使用時(shí),導(dǎo)體長(zhǎng)期允許工作溫度不超過(guò)70℃,短路時(shí)(最大短路時(shí)間5S),導(dǎo)體最高溫度不超過(guò)160℃;

      電纜敷設(shè)的最低溫度為0℃敷設(shè)時(shí)最小彎曲半徑,無(wú)鎧裝層時(shí)應(yīng)不小于電纜外徑的10倍,有鎧裝層時(shí)應(yīng)不小電纜外徑的15倍。

      For normal use of halogen free low-smoke cable, the permittedlongtime operating temp. of conductor is 90℃;For short circuit(the longest time is 5s), the.temp of conductor max should notexceed 250c.

      For normal use of low-halogen low-smoke cable,the permitted long-time oper-ating temp.of conductor shouldnot exceed 70℃;For short cincuit(the longest time is 5s), temp,of conductor max should not exceed 160℃

      The lowest temp forthe laying of cables is o℃ .As for the shortest bend cadius: Forcables without sheath,it should not be shorter than,10 times of outer diam;For cables with sheath; it should not beshort than 15times of outer diam.